Note : We Will Not Share Your Information To Any Third Parties.
Our inventory is replete with top-quality NSN parts like those with the FSC 5930 Switches and NSN 5930-01-154-0550. For additional specifications regarding your product needs, you can also search for items by their CAGE code, such as 00AC6, and many other designations. Once you have had time to browse through our selection of Daniels Equipment Company Inc parts and more, we invite you to take advantage of our RFQ service by requesting a quote for your comparisons on parts of interest. As you fill out the form on this page, be sure to include relevant details like your desired part quantity and expected delivery date so an account manager can calculate a quote that has been customized to your specifications. Kick off the procurement process with the submission of the form below to see why customers continue to rely on The NSN Distributor for all their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-154-0550 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 011540550 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
TU7244 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
ABHP | OVERALL LENGTH | 2.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.105 INCHES MAXIMUM |
ABPM | BODY DIAMETER | 0.910 INCHES MINIMUM AND 0.930 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.250 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.366 INCHES MINIMUM AND 0.396 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.625 INCHES MINIMUM AND 1.688 INCHES MAXIMUM |
AGAV | END ITEM IDENTIFICATION | FORCE PROVIDER |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AWTN | OPERATING TEMP RATING | 350.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET AND SLOT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | QUICK DISCONNECT,MALE |
CTHF | CONTACT LOAD CURRENT RATING | 12.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 6.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 6.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 135.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 125.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 12.0 DC AT SEA LEVEL THIRD VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 277.0 AC AT SEA LEVEL FIRST VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
STYL | STYLE DESIGNATOR | DISC W/FLANGE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.